PSC SCBA
Model: HG-RHZKF6.8/30 – Self-Contained Breathing ApparatusStandards: EN137 / NFPA 1981 / ISO 23269-1
1. Product Overview
Positive-pressure, self-contained open-circuit compressed air respirator.Provides respiratory protection in fire, chemical, and confined space environments.
2. Working Principle
- Open cylinder valve to release high-pressure air.
- Air passes through cylinder valve and pressure reducer, first-stage pressure reduction to ~0.7 MPa.
- Medium-pressure air flows to supply valve, adjusts pressure per user inhalation.
- Regulated air enters mask for breathing.
- Exhaled air discharged through mask exhalation valve, maintains one-way airflow.
3. Components
- Facepiece/Mask: Polycarbonate lens (anti-fog, anti-scratch), silicone/rubber seal
- Air Cylinder: 6.8 L, 30 MPa working pressure, aluminum/composite material
- Pressure Reducer: Two-stage automatic regulator
- Harness & Backplate: Ergonomic, adjustable, flame-retardant
- Alarms: Audible EOSTI alarm (5.5±0.5 MPa, >90 dB), optional PASS device
4. Specifications
- Product model: HG-RHZKF6.8/30
- Cylinder capacity: 6.8 L
- Cylinder pressure: ≤30 MPa
- Gas storage capacity: 2040 L
- Theoretical usage time: 68 min (breathable air volume / user’s air consumption)
- Rated duration: 30 min
- Alarm pressure: 5.5±0.5 MPa
- Alarm sound intensity: >90 dB
- Max gas supply flow: ≥500 L/min
- Static pressure: ≤500 Pa
- Inspiratory resistance: ≤500 Pa
- Exhalation resistance (25 breaths/min): ≤700 Pa
- Exhalation resistance (40 breaths/min): ≤1000 Pa
- Whole machine weight (without air): 8.0 kg
- Operating temperature: -30°C ~ +60°C
- Mask lens: Polycarbonate, anti-fog, anti-scratch
- Approvals: EN137 Type 2, NFPA 1981, ISO 23269-1
5. Applications
- Firefighting and rescue
- CBRN environments
- Confined space operations
- Industrial emergency response
6. Storage & Maintenance
- Store in cool, dry, ventilated area
- Inspect before each use
- Follow manufacturer’s maintenance schedule for cylinders, regulators, and masks