A2E2P3 RD40 Combination Filter Canister

Category Tags ,

A2E2P3 Filter Canister Datasheet

Product Overview

Combined filter for organic gases/vapors and particulates. Complies with EN 14387:2004+A1:2008 (EU PPE Directive 2016/425). Interface: RD40 (EN 148-1) thread; compatible with most European half/full-face masks. Marked A2 E2P3 R D for multi-shift, high-dust use.

1. Basic Specifications

Parameter Details
Model A2E2P3 RD40
Protection Type Combined gas & particulate filter
Standard EN 14387:2004 + A1:2008 (PPE: EU 2016/425)
Thread RD40 × 1/7″ (EN 148-1)
Housing Polypropylene / ABS
Filter Media Impregnated activated carbon + P3 microfiber glass
Weight approx. 320–380 g
Dimensions Ø110 mm × H95 mm (standard)
Color Code Brown (A2) + Yellow (E2) + White (P3)
Markings A2 E2 P3 R D
Shelf Life 5 years (sealed original package)

2. Protection Performance

Gas Protection (Class 2)

Test conditions: 30 L/min, 5000 ppm, 70% RH
Type Protected Gases Breakthrough Min Duration Typical Duration
A2 Organic vapors (bp >65°C): toluene, gasoline, solvents 10 ppm (cyclohexane) 35 min 48–55 min
E2 Acid gases: SO₂, HCl, acid mists 5 ppm (SO₂) 20 min 25–30 min

Particulate Protection (Class 3)

Parameter Standard Test Result
Efficiency ≥99.95% 99.995–99.999%
Penetration ≤0.05% 0.0007–0.003%
Particles Non-oily & oily (NaCl & paraffin oil) Passed
Durability R = reusable (multi-shift) Yes
Dust Resistance D = high-dust performance Yes

3. Breathing Resistance

Flow Rate Max Limit Typical Value
30 L/min (normal) < 2.6 mbar 1.5–1.9 mbar
95 L/min (heavy) < 9.8 mbar 6.0–7.0 mbar

4. Applications

  • Chemical industry (solvents, acid gases)
  • Laboratories (organic vapors, acid mists)
  • Metal treatment & smelting (fumes, acids)
  • Construction & demolition (dust + gases)
  • Waste treatment & remediation

5. Compatibility

Compatible with full-face/half-masks with RD40 (EN 148-1) thread

 