Protection Type
|
Protected Substances
|
Breakthrough
|
Required Duration
|
Tested Duration
|
|
A2 (Organic Gases)
|
Boiling point >65℃ organic vapors (cyclohexane, toluene, gasoline)
|
10ppm (cyclohexane)
|
35min
|
48-53min
|
|
B2 (Inorganic Gases)
|
Cl2, H2S, HCN
|
Cl2=0.5ppm; H2S=10ppm; HCN=10ppm
|
Cl2=20min; H2S=40min; HCN=25min
|
Cl2=25-32min; H2S=46->70min; HCN=28-35min
|
|
E2 (Acid Gases)
|
SO2, hydrochloric acid vapor, HF
|
5ppm (SO2)
|
20min
|
22-28min
|
|
K2 (Ammonia/Derivatives)
|
NH3, methylamine, ethylamine
|
25ppm (NH3)
|
40min
|
45-52min
|
|
Test Aerosol
|
Max Penetration
|
Measured Penetration
|
Test Flow
|
|
NaCl Aerosol
|
0.05%
|
0.0008%-0.003%
|
95L/min
|
|
Paraffin Oil Aerosol
|
0.05%
|
0.0007%-0.0038%
|
95L/min
|
|
Breathing Condition
|
Flow Rate
|
Inhalation Resistance
|
|
Normal Breathing
|
30L/min
|
1.4-1.8mbar
|
|
High Breathing
|
95L/min
|
5.7-6.6mbar
|
|
Standard Type
|
Details
|
|
EU Standard
|
EN 14387:2004 + A1:2008 (replaced by EN 14387:2021)
|
|
Interface Standard
|
EN 148-1 (latest: EN 148-1:2018)
|
|
EU Regulation
|
2016/425 (PPE Regulation)
|
|
Chinese Standard
|
GB 2890-2009
|
|
Item
|
Requirement
|
|
Ambient Temperature
|
0℃ – 60℃
|
|
Relative Humidity
|
20% – 95%
|
|
Oxygen Concentration
|
≥17% (volume); prohibited if lower
|
|
Prohibition
|
Unlisted hazardous gas environments
|
|
Item
|
Requirement
|
|
Temperature
|
-20℃ – 50℃
|
|
Relative Humidity
|
<80%
|
|
Storage Environment
|
Cool, dry, ventilated; away from high temperature, fire, corrosives; no direct sunlight
|
|
Shelf Life
|
5 years (sealed original packaging); marked on label/packaging
|
|
Industry/Scenario
|
Protected Against
|
|
Chemical Industry
|
Organic/inorganic/acid gases, ammonia leaks
|
|
Laboratories
|
Harmful gases, dust from chemical experiments
|
|
Construction
|
Dust, sandy environments, decoration processes
|
|
Machining
|
Dust, fumes from machining operations
|